Alpha Technologies IPDP - 00C Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
20
Parameter
Value
Description
Default
57
t
DTMF tone duration (ms)
5 (100ms)
58
m
Space duration between DTMF tones
(ms)
5 (100ms)
59
f
Recall duration (ms)
1 (100ms)
50
p
Pause duration (ms)
8 (800ms)
t DTMF tone duration is determined by the formula:
(entered number + 5) x 10 = tone duration [ms]
[range 1-0 i.e. 60-150ms]
m Space duration between DTMF tones is determined by the formula:
(entered number + 5) x 10 = gap duration [ms]
[range 1-0 i.e. 60-150ms]
f Recall duration is determined by the formula:
entered number x 100 = Recall duration [ms]
[range 1-6 i.e. 100-600ms]
p Pause duration is determined by the formula:
entered number x 100 = pause duration [ms]
[range 5-0 i.e. 500-1000ms]
p time is simultaneously the duration of interdigit gap at pulse dialling.
Parameter
Value
Description
Default
5*1
x
Number of busy tones before hahg up
6
x is number of busy tones before hahg up by next table:
x
number of busy tones
x
number of busy tones
1
4
5
8
2
4
6
8
3
6
7
10
4
6
8
10
Vue de la page 19