Alpha Technologies IPDP - 00C Manuel d'utilisateur Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
23
Parametr
Value
Description
Default
6
z
Acoustic signalling
3 and 9
In default the unit produces acoustic signals. It can occasionally cause a problem
of incorrect detection of tones by PBX. By changing parametez“ you can switch
off this acoustic signalization. The values are:
z=0 all signalling is switched off
z=1 pick up and hang up tones are active only
z=2 other tones active only (except pick up and hang up)
z=3 all tones are active (default)
It is possible to generate an audible signal (only in mode m=1) to alert visitors
that the door is unlocked so that they can enter. This is especially useful when
using a DC power source, as lock release may be silent.
z=8 signalling is active
z=9 signalling is unactive
Parameter
Value
Description
Default
6*
t
Delay of line connection (Siemens PBX)
1
Setes a delay for line pick-up (OFF HOOK) for new PBX types (particularly
Siemens):
t=1 standard operation
t=0 delayed start
5.8 Overview of Parameters
Parameter
Value
Description
Default
1
t nn…
No. nn under button t
-
2
t nn…
No. nn under button t
-
31
r
Relay mode
1
32
hhhhhh
External access code in DAY + NIGHT
mode
-
33
hhhhhh
External access code in DAY mode
-
34
hhhhhh
External access code in NIGHT mode
-
35
aa
Internal access code
55
36
ss
Relay closing time
05
Vue de la page 22